Industry & energy
Energy efficiency for boilers and heating plants: how to cut fuel use
In boiler houses, heating plants and industrial sites, efficiency is not measured per kilometre but as the ratio of fuel burned to energy delivered. That ratio sets the cost of every kilowatt-hour of heat and is the core energy-efficiency metric.
7 min read
The right metric: fuel per unit of energy
Total fuel use depends on winter severity, connected customers and production plans. Track specific consumption instead: litres of heavy oil or diesel, or cubic metres of gas, per MWh of heat delivered or per unit of product.
- Heating plants: fuel per MWh delivered, corrected for heating degree days.
- Industrial kilns and dryers: fuel per tonne of product.
- Generators: fuel per kWh produced.
Where fuel is lost
The largest losses usually come from incomplete combustion, deposits on heat-transfer surfaces, excess air and frequent burner cycling. Each raises fuel use without delivering more energy.
Regular burner tuning, surface cleaning and flue-gas analysis come first. Only then does it make sense to measure the effect of additional solutions.
How the CFSS system improves efficiency
The Comet Fuel Saving System acts on the fuel before combustion: the reformulator, a device fitted on the fuel line, changes the fuel structure so combustion is more complete. More complete combustion means more energy from the same fuel and fewer deposits.
For liquid fuels the guaranteed minimum saving is 7%, with typical results of 8–12%. For gas we guarantee 5%. JKP Gradska toplana measured 12% higher efficiency, and RAK Ceramics measured 5.5% on natural gas.
How to verify savings on site
Take a baseline period with the same operating regime and compare specific consumption before and after installation. For heating plants, always correct for outdoor temperature, since a colder month naturally uses more fuel.
- One data source: fuel meters and delivered-heat meters.
- Correction for degree days or production volume.
- Flue-gas analysis before and after as extra confirmation.
FAQ
Questions we are asked most
- Does CFSS work on gas?
- Yes. The guaranteed minimum saving is 5% on natural gas and at least 7% on liquid fuels.
- Does installation require a plant shutdown?
- Fitting on the fuel line is short and scheduled with your team at a time that does not disrupt energy supply.
- How are savings measured when winters differ?
- Fuel is compared per unit of delivered energy and corrected for heating degree days, so temperature differences do not distort the result.
Want the numbers for your own fleet?
We measure consumption before and after installation on your own vehicles, under an agreed methodology, with a contracted minimum saving of 7% on liquid fuels.
Book a presentationRelated pages
- Fuel saving system
How CFSS works for fleets and industry.
- Verified results
Measured savings at named clients.